INDUSTRIAL EQUIPMENT & SOLUTIONSLINE: pick_113[email protected]095-465-2425
TH
Articles / SPI KNOWLEDGE

SPI KNOWLEDGE

How much airflow does an exhaust hood need? A worked CFM example

Estimate airflow for a rectangular exhaust hood from its opening area and reference air velocity. See a 6,100 CFM example for two hoods and what to collect before selecting a blower.

How much airflow does an exhaust hood need? A worked CFM example

What to measure

Measure the width and length of the hood opening, note whether the hood is wall-mounted or an island hood, and list the hoods that will run together. Multiply the opening area in square feet by the reference air velocity in feet per minute to estimate airflow in CFM. Hood geometry, distance from the source and cross-draughts affect capture in practice.

Two wall-mounted hoods

  1. A 0.75 × 2 m hood gives about 2,098 CFM, rounded up to 2,100 CFM in the example.
  2. A 0.70 × 4 m hood gives about 3,916 CFM, rounded up to 4,000 CFM in the example.

The two hoods together give 6,100 CFM, or about 10,364 m³/h. The rounding rules are part of the example. Confirm the design values for the actual installation.

Try the hood airflow calculator and copy the result for LINE

What to collect before choosing a blower

  • Hood dimensions and type, distance from the source, contaminant type and the hoods that will run simultaneously
  • Inlet and outlet duct dimensions and lengths, elbows, transitions, dampers and filters
  • The system pressure at the required airflow, with its unit and whether it is static or total pressure if known

Use airflow and pressure at the same operating point to compare manufacturer curves. Catalog equipment is provided as a starting point for enquiries. Have a qualified specialist review and test installations that control hazardous dust or fumes.

See the HSE guide to local exhaust ventilation and the AMCA guide to fan curves.

RELATED EQUIPMENT

Related products

Website publisher and catalog enquiries: SPI Intertrade

Original article source ↗

Confirm site conditions and the manufacturer’s instructions before applying this information.

ProductsCall usLINE ↗