INDUSTRIAL EQUIPMENT
Active Power Filter (APF)
Model / SKU: —
Delta PQC Series APF for harmonic filtering, reactive-power compensation and load-imbalance correction. Manufacturer instant response: < 100 µs.
Share the model, quantity and application so our team can confirm the selection.
Product details
Delta PQC Series APF is an active harmonic filter for improving electrical power quality. It compensates reactive power and helps reduce load imbalance, with modules that can be added to suit the system.
The manufacturer specifies an instant response below 100 microseconds (µs). This differs from full response time: rear/front connection models specify full response below 20 milliseconds (ms). Select the variant for the required voltage and compensation capacity.
Product questions
What is this product?
Active Power Filter (APF) is listed under Automation & Control.
Which technical data is stated for this record?
The referenced source states: Selectable harmonic range (400 V): 2nd–50th order; Instant response time: < 100 µs; Full response time (rear/front connection): < 20 ms; Rated frequency: 50 (60) Hz ±10%; Post-filter harmonic distortion, subject to manufacturer conditions: THDv < 3% · THDi < 5%; Power factor with sufficient APF capacity: PF ≥ 0.99. Review the specification table and its source/configuration notes before ordering.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Ask our team |
|---|---|
| Model / SKU | Active Power Filter (APF) |
| Category | Power Quality Equipment |
| Selectable harmonic range (400 V) | 2nd–50th order |
| Instant response time | < 100 µs |
| Full response time (rear/front connection) | < 20 ms |
| Rated frequency | 50 (60) Hz ±10% |
| Post-filter harmonic distortion, subject to manufacturer conditions | THDv < 3% · THDi < 5% |
| Power factor with sufficient APF capacity | PF ≥ 0.99 |
| Reactive power compensation | Inductive and capacitive loads |
| Communication | Modbus RTU (RS-485) · Modbus TCP/IP (Ethernet) |
These values describe the manufacturer’s rear/front connection Delta PQC APF family at 400 V. They do not apply to every APF version. THD and power-factor performance depend on load and available compensation capacity; confirm the full model code.
Documents & catalogs
Related reading
The kW/ton (pronounced "kilowatt per ton") value of the Chiller.
The kW/ton (pronounced "kilowatt per ton") value of a Chiller is: The meaning of kW/ton is the value used to measure. Energy effic
Read article ↗
Selecting Automation Equipment: PLCs, Drives, Sensors and Control Systems
First separate the functions to be controlled, then collect model codes, electrical supply, signals and connected equipment to com
Read article ↗