VENZ
centrifugal water pump Venz model VR
Model / SKU: —
Features - Open-impeller centrifugal pump - Low to moderate flow rate - Open impeller designed for pumping water or liquids containing other materials, reducing the risk of impeller blockage. - Maximum particle size 10 mm - Pipe size 1.5” x 1.5” - Motor size 1 HP - Maximum delivery head 20-10.5 m - Water flow rate 2.4-16.8 L / min - Electrical supply: two-wire 1 phase 220v and 3 phase 380v - High-quality corrosion-resistant cast-iron pump casing helps reduce maintenance costs. - Rust-resistant b
Share the model, quantity and application so our team can confirm the selection.
Product details
Features - Open-impeller centrifugal pump - Low to moderate flow rate - Open impeller designed for pumping water or liquids containing other materials, reducing the risk of impeller blockage. - Maximum particle size 10 mm - Pipe size 1.5” x 1.5” - Motor size 1 HP - Maximum delivery head 20-10.5 m - Water flow rate 2.4-16.8 L / min - Electrical supply: two-wire 1 phase 220v and 3 phase 380v - High-quality corrosion-resistant cast-iron pump casing helps reduce maintenance costs. - Rust-resistant brass impeller helps extend service life. - Stainless-steel shaft SUS 304 corrosion-resistant for longer service life. - Maximum liquid temperature 90 C Suitable for various operating conditions - Maximum suction depth 8 m - Motor wound with high-quality copper wire 100% helps maintain motor speed and full performance for a longer service life. - Insulation CLASS F Heat resistance up to 155°c Suitable for various applications - IP55 Protects against small dust particles and rain droplets or large water drops, helping extend service life and reduce costs. - Maximum ambient operating temperature 40°c for durable, long-term operation. Applications - Suitable for applications requiring low flow rates and pumping liquids containing materials such as gravel or sediment. - Suitable for agricultural water systems. - Suitable for pumping from ponds, canals, rivers and reservoirs. - Suitable for general-purpose water transfer. - Centrifugal pump, water pump and agricultural water pump VENZ High efficiency meeting international standards
Technical values explicitly stated by the source: Length / size 10 mm; Horsepower 1 HP; Capacity 2.4-16.8 L
Product questions
What is this product?
centrifugal water pump Venz model VR is listed under Pumps and water systems, brand VENZ.
Which technical data is stated for this record?
The referenced source states: Length / size (source-stated): 10 mm; Horsepower (source-stated): 1 HP; Capacity (source-stated): 2.4-16.8 L; Voltage (source-stated): 220 V; Voltage (source-stated): 380 V; Protection rating (source-stated): IP55. Review the specification table and its source/configuration notes before ordering.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | VENZ |
|---|---|
| Model / SKU | centrifugal water pump Venz model VR |
| Category | Centrifugal Water Pumps |
| Length / size (source-stated) | 10 mm |
| Horsepower (source-stated) | 1 HP |
| Capacity (source-stated) | 2.4-16.8 L |
| Voltage (source-stated) | 220 V |
| Voltage (source-stated) | 380 V |
| Protection rating (source-stated) | IP55 |
Only values explicitly stated with technical units in the original title or description are listed. These are partial facts and may describe a series range, not a complete datasheet. Confirm the variant and configuration before ordering.
Documents & catalogs
Related reading
Evaluation principles Chiller vs VRF system installation cost
Evaluation principles The cost of installing a Chiller vs VRF system is not just looking at the "price of the machine" but having
Read article ↗District Cooling System (DCS)
What is District Cooling? (The system work is explained clearly and is easy to understand.) District Cooling System (DCS) is a cen
Read article ↗Key Technical Differences: VRF vs Chiller
✔️ 1. Key Technical Differences: VRF vs Chiller (A) VRF system — Variable Refrigerant Flow Principle: Pipe refrigerant from Outdoo
Read article ↗Related equipment
All related articles (20)
- EQ pipe (Equalizer Pipe) in Cooling Tower
- water pump
- Water pump system in Chiller work
- Cooling Tower
- Calculating pump drive power
- Pump : Centrifugal pump or basic centrifugal pump
- History and types of each type of pump
- Calculating electricity costs for electric centrifugal pumps
- How to choose a water pump for your application
- Choosing industrial and household water pumps for the right application
- Which water supply system suits a multistory home?
- 3 checks to make before operating a water pump
- Why does the pump run but no water flows?
- Determining head when selecting a water pump
- Centrifugal pump troubleshooting: theory, problems and remedies
- Selecting Pumps and Water Systems: Compare Pump Types and Prepare a Quotation Enquiry
- Troubleshooting a Centrifugal Pump