EUROVENT
Axial fan with belt drive ALc Series
Model / SKU: —
Axial fan with belt drive ALc Series Product Type: Axial fan with belt drive ALc Series Product Type: Axial fan (belt drive) Pressure type: Low level pressure Structure: Axial flow fans, both wall-mounted PL, AM AL ALc and RF types. Construction material is made of painted steel. Epoxy heat treatment for strength Propellers are made from Polymer material imported from Italy. Can withstand temperatures up to 120 degrees Celsius and can withstand many types of chemicals. The blades can be easily a
Share the model, quantity and application so our team can confirm the selection.
Product details
Axial fan with belt drive ALc Series Product Type: Axial fan with belt drive ALc Series Product Type: Axial fan (belt drive) Pressure type: Low level pressure Structure: Axial flow fans, both wall-mounted PL, AM AL ALc and RF types. Construction material is made of painted steel. Epoxy heat treatment for strength Propellers are made from Polymer material imported from Italy. Can withstand temperatures up to 120 degrees Celsius and can withstand many types of chemicals. The blades can be easily adjusted to adjust the angle of the wind. In case you want to use heat, you can change the blades to aluminum materials as well. Usage: Suitable for smoke extraction. Ventilate the wall Areas with dust and humidity Cement factory, paper factory, drying equipment Or used in heat exchange systems, cold rooms, Cooling Towers can be used at a maximum temperature of 300 degrees Celsius Air Volume: 80-1100 m3/min St. Pressure: 4-70 mmH2O Impeller Dia (mm): 400-1000
Product questions
What is this product?
Axial fan with belt drive ALc Series is listed under Fans and blowers, brand EUROVENT.
Which technical data is stated for this record?
The referenced source states: Catalogue flow rate: 80–1100 m³/min; Catalogue impeller diameter range: 400–1000 mm. Review the specification table and its source/configuration notes before ordering.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | EUROVENT |
|---|---|
| Model / SKU | Axial fan with belt drive ALc Series |
| Category | Fans and blowers |
| Catalogue flow rate | 80–1100 m³/min |
| Catalogue impeller diameter range | 400–1000 mm |
TN Metalworks catalogue values describe the referenced model or series. Actual values depend on the selected model and configuration. Check the documentation for the ordered model. Maximum flow and pressure are not a single operating point.
Documents & catalogs
The source catalog has no attached document for this record.
Request product documentation ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Low Noise Duct Design
Low Noise Duct Design is a matter of controlling air speed + pressure + vibration + selecting equipment. From the origin to the di
Read article ↗Related equipment
All related articles (67)
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Fans and Blowers: Information to Prepare before Comparing Models
- Managing Heat in Buildings and Factories
- Installing Factory Ventilation Fans