INDUSTRIAL EQUIPMENT & SOLUTIONSLINE: pick_113spi2553@hotmail.com095-465-2425
TH
Articles / SPI KNOWLEDGE

SPI KNOWLEDGE

The difference between fans and blowers

The difference between fans and blowers fan is equipment used to move air at low pressure. Fans used in engineering are mainly applied to drying agricultural materials, ventilation, cooling, conveying and heating. The term fan ( Fan) describes equipment operating at a pressure below 1 meters of water or 1 pounds per square inch or 27.7 inches of water or…

The difference between fans and blowers

The difference between fans and blowers

fan is equipment used to move air at low pressure.   Fans used in engineering are mainly applied to drying agricultural materials, ventilation, cooling, conveying and heating. The term

fan ( Fan)  describes equipment operating at a pressure below 1 meters of water   or 1 pounds per square inch   or 27.7 inches of water   or 1,000 millimeters of water. Equipment in this category is generally called Centrifugal Fans, Fan and Exhausters

blower ( Blower)  describes equipment operating at pressures above 1 meters of water and up to 10 meters of water
Where airflow must be produced at a pressure above 1 bar or 10 meters of water   equipment called an air compressor ( Air Compressor)

Comparison table for selecting equipment

Start by comparing the pressure required by the system with the ranges defined in the article, then choose the corresponding equipment category.

Mobile viewing: Scroll the table horizontally to see all columns.

Benchmark Fan Blower When the pressure is higher than that
Operating pressure range stated in the article Below 1 meter of water, or 1 pound per square inch, or 27.7 inches of water Above 1 meter of water and up to 10 meters of water Above 1 bar or 10 meters of water: the article identifies this as the air compressor category
Equipment categories identified in the article Centrifugal Fans, Fan and Exhausters BlowerAir Compressor
Application examples stated in the article Drying agricultural materials, ventilation, cooling, conveying and heating Consider when the required pressure falls within the blower range Consider when the required pressure exceeds the blower range
Initial selection sequence Check whether the required system pressure is below 1 meter of water Check whether the pressure is above 1 and up to 10 meters of water If it exceeds 10 meters of water, consider air compressors as discussed in the article

Note: This table only summarizes the original article. Review the system details and actual site conditions before choosing equipment.

Browse related fans and blowers