Kruger
BNB Series - Plenum Fans - Backward Wheels
Model / SKU: —
The BNB series is a backward curved plenum fan. The full range of BNB series is AMCA certified to Air, Sound and FEG. Plenum fans are designed for air handling application where the fan wheel operates without a housing. It operates inside a plenum. This results in saving of space normally occupied by the fan housing, transition and diffusers. The fan wheel pressurizes the entire plenum in which the fan is installed. The allows air ducts to be directly connected from any direction of the plenum.
Share the model, quantity and application so our team can confirm the selection.
Product details
The BNB series is a backward curved plenum fan. The full range of BNB series is AMCA certified to Air, Sound and FEG. Plenum fans are designed for air handling application where the fan wheel operates without a housing. It operates inside a plenum. This results in saving of space normally occupied by the fan housing, transition and diffusers. The fan wheel pressurizes the entire plenum in which the fan is installed. The allows air ducts to be directly connected from any direction of the plenum. The compact size of the plenum fan makes it an excellent selection for retrofit and replacement application and for variable air volume systems. There are three types of the BNB series, i.e. BNB-R (regular type), BNB-P (high pressure type), and BNB-Q (high volume ratio type). The operating limit of BNC series is set according to the requirement of Class 1, 11 and 111 limit as defined in AMCA standard 99-16. The BNC series is available in Direct Driven and Belt Driven.
Product questions
What is this product?
BNB Series - Plenum Fans - Backward Wheels is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | BNB Series - Plenum Fans - Backward Wheels |
| Category | Centrifugal Fan for HVAC |
Specifications Quick Facts • Available backward curved wheel • Size from 315 to 1400mm • Capacities to 170,000 m3/h • Static pressure up to 2600 Pa • Suitable to use for AHU and clean room Application For supply or exhaust application in commercial, institutions and industrial HVAC systems. Testing • Both air and sound performance ratings are test in accordance to AMCA210 and AMCA300 Standards. • All wheels are statically and dynamically balanced to ISO1940 and AMCA204/3 - G2.5 Standards. Accessories Inlet Guard This may be required in some industrial and safety regulations. These are available upon request. Construction Wheel The wheel of BNC series have backward curved blades manufactured in mild steel with polyester powder coating finish. Shaft Shafts are manufactured from C45 carbon steel. All dimensional tolerances of the shaft are fully checked to ensure precision fit. All shafts are coated with an anti-corrosion varnish after assembly. Bearings Bearings used are either deep groove ball bearing type with an adaptor sleeve or spherical roller bearings type sealed at both sides for different duty application. Balancing Quality • All wheels are statically and dynamically balanced to ISO 1940 and AMCA 204-G2.5 standard. • All fans after assembly are trim balanced to ISO 1940 and AMCA 204-G2.5 standard. • Standard lower than G2.5 is available upon request.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Measuring the wind speed in front of the kitchen hood (Kitchen Hood Face Velocity)
Measuring the wind speed in front of the Kitchen Hood (Kitchen Hood Face Velocity) has the main objective to confirm that the Hood
Read article ↗Related equipment

ADA Series - Direct Coupling Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ADA Series - Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ASA Series - Single Inlet Centrifugal Fans - Airfoil Wheels
Kruger

BDB Series - Direct Coupling Double Inlet Centrifugal Fans – Backward Wheels
Kruger
All related articles (77)
- Low Noise Duct Design
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Exhaust duct specs for “Kitchen Exhaust Duct”
- Problems frequently encountered in “Commercial Kitchen System”
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- KRUGER BNB Series
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Calculating the size of the Smoke Exhaust Fan (for exhausting smoke)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Benefits of Cooljet fans for industrial systems
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 impeller types and how centrifugal fans work
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Choosing a Blower for Industrial Work
- Installing Factory Ventilation Fans