Kruger
CFC Series - Direct Driven and Belt Driven
Model / SKU: —
CFC Series is a compact cabinet centrifugal fan is designed for supply, exhaust and pressurization in general clean air, grease laden air and smokespill application. It is compact, easy to install and service, generates high static pressure and low noise. Both air and sound performance ratings are tested and certified by AMCA, in accordance to AMCA211 and AMCA311 Standards. High temperature (up to 400°C/2Hrs) in accordance with EN12101-3 certification by TÜV SÜD a third-party globally renowned t
Share the model, quantity and application so our team can confirm the selection.
Product details
CFC Series is a compact cabinet centrifugal fan is designed for supply, exhaust and pressurization in general clean air, grease laden air and smokespill application. It is compact, easy to install and service, generates high static pressure and low noise. Both air and sound performance ratings are tested and certified by AMCA, in accordance to AMCA211 and AMCA311 Standards. High temperature (up to 400°C/2Hrs) in accordance with EN12101-3 certification by TÜV SÜD a third-party globally renowned testing and certification organisation.
Product questions
What is this product?
CFC Series - Direct Driven and Belt Driven is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | CFC Series - Direct Driven and Belt Driven |
| Category | Fan in the air duct system |
Specifications Quick Facts • Backward curved • Size from 315 to 800 • Capacity up to 30,000 m3/h • Static pressure up to 1,000 Pa • Compact cabinet, easy to installation and service. suitable for clean air Airstream operating temperatures • Clean air standard ventilation application -20°C to +55°C. • Kitchen (grease laden air) application up to +205°C / 400°F. • High temperature smokespill application up to 400°C/2Hrs certified. Motor All CFC Series fans are supplied with a wide variety of both 1PH and 3PH AC, PM and EC, standard and high temperature rated motors. Accessories • "Double skin" cabinet with acoustic and thermal insulation. • Inlet and outlet safety guard. • Flexible duct for normal and high temperature up to 400˚C. • Vibration isolator for ceiling hung or floor mounted installations. • Spark resistance construction per AMCA 99. • Safety electrical switch. • Belt cover isolates drive sets from airstream and protection from rotating pulleys and belts. Construction Cabinet With high gloss surface finished manufactured from ZERO spangle galvanized steel Kruger's 3rd Generation Plenum Backward Curved Wheel Specifically optimized for high efficiency in an inline configuration. Wheel manufactured in steel finished in zinc rich primer and polyester powder coating with salt spray rating up to 1000 hours (ASTM B117). All wheels are statically and dynamically balanced to G2.5 (ISO 21940). High Precision Shaft Belt drive shaft manufacture from C45 steel with g6 tolerance (ISO286-2), to minimize eccentricity of shaft leading to lower vibration and longer bearing life. Extended Operating Life Sealed bearings suitable for L10, >75,000 operating hours at maximum speed. Extended operating life construction of L10, >200,000 operating hours available upon request. Vibration balanced to G2.5 in accordance with ISO14694/AMCA 204 standards. Service Friendly Motor and drive outside casing and for easier belt adjustment and replacement. Built-in inlet and outlet flange for easy duct connection.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Measuring the wind speed in front of the kitchen hood (Kitchen Hood Face Velocity)
Measuring the wind speed in front of the Kitchen Hood (Kitchen Hood Face Velocity) has the main objective to confirm that the Hood
Read article ↗Related equipment
All related articles (77)
- Low Noise Duct Design
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Exhaust duct specs for “Kitchen Exhaust Duct”
- Problems frequently encountered in “Commercial Kitchen System”
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- CFC Series - Direct Driven and Belt Driven
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Calculating the size of the Smoke Exhaust Fan (for exhausting smoke)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Benefits of Cooljet fans for industrial systems
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 impeller types and how centrifugal fans work
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Choosing a Blower for Industrial Work
- Installing Factory Ventilation Fans





