Kruger
eBNC Ecowatt EC Plenum Fan Series
Model / SKU: —
Available in 9 different models, the eBNC Ecowatt is an EC Plenum Fan Series. It comes with an aluminium material backward curved impeller with an efficient EC motor with drives and electronics that operates between full to partial speeds to meet the choice of customers who require highly efficient overall fan system efficiency of well over 60%. The integrated speed drive allows for simple speed control, PI control with sensor input or MODBUS high level interface connection over RS485 serial con
Share the model, quantity and application so our team can confirm the selection.
Product details
Available in 9 different models, the eBNC Ecowatt is an EC Plenum Fan Series. It comes with an aluminium material backward curved impeller with an efficient EC motor with drives and electronics that operates between full to partial speeds to meet the choice of customers who require highly efficient overall fan system efficiency of well over 60%. The integrated speed drive allows for simple speed control, PI control with sensor input or MODBUS high level interface connection over RS485 serial connection. Due to it's light weight and compactness, the eBNC Ecowatt EC Plenum Fan is an ideal replacement fan for AHU retrofit application as well as new installations where energy consumption is a critical consideration.
Product questions
What is this product?
eBNC Ecowatt EC Plenum Fan Series is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | eBNC Ecowatt EC Plenum Fan Series |
| Category | Centrifugal Fan for HVAC |
Specifications Quick Facts • Size eBNC 315 to eBNC 630 • High static pressure up to 1500Pa on eBNC 315/355 • Aluminium wheel with backward curved blade. • 3-phase EC motor with IE4 efficiency. • Maximum power input from 1.85 kW to 3.30 kW • AMCA certified air, sound performance & FEI • Energy saving high efficiency • Speed control via 0-10V or 4-20mA speed regulation and MODBUS over RS485 serial connection. • Simple, easy to handle, light and compact.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Measuring the wind speed in front of the kitchen hood (Kitchen Hood Face Velocity)
Measuring the wind speed in front of the Kitchen Hood (Kitchen Hood Face Velocity) has the main objective to confirm that the Hood
Read article ↗Related equipment

ADA Series - Direct Coupling Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ADA Series - Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ASA Series - Single Inlet Centrifugal Fans - Airfoil Wheels
Kruger

BDB Series - Direct Coupling Double Inlet Centrifugal Fans – Backward Wheels
Kruger
All related articles (76)
- Low Noise Duct Design
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Exhaust duct specs for “Kitchen Exhaust Duct”
- Problems frequently encountered in “Commercial Kitchen System”
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Calculating the size of the Smoke Exhaust Fan (for exhausting smoke)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Benefits of Cooljet fans for industrial systems
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 impeller types and how centrifugal fans work
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Choosing a Blower for Industrial Work
- Installing Factory Ventilation Fans

