Kruger
KAT Series - Double Inlet Centrifugal Fans - Forward Curved
Model / SKU: —
The KAT series is DIDW centrifugal fan with forward curved (FC) impellers. The fans are suitable for supply and exhaust applications in commercial, process and industrial HVAC systems. Ranges KAT-9/7 to KAT 18-18 are AMCA certified to Air, Sound and FEG. The KAT series is available in Type S and C. KAT series is also available in twin fan version with two double inlet fans mounted on the same shaft. KAT fans are operated at relatively low speeds and are used to deliver large air volumes against
Share the model, quantity and application so our team can confirm the selection.
Product details
The KAT series is DIDW centrifugal fan with forward curved (FC) impellers. The fans are suitable for supply and exhaust applications in commercial, process and industrial HVAC systems. Ranges KAT-9/7 to KAT 18-18 are AMCA certified to Air, Sound and FEG. The KAT series is available in Type S and C. KAT series is also available in twin fan version with two double inlet fans mounted on the same shaft. KAT fans are operated at relatively low speeds and are used to deliver large air volumes against relatively low static pressures. The inherently light construction of the forward curved wheel does not permit it to be operated at speeds needed to generate high static pressure. The typical application range of this type of fan is from 30 to 80% wide open airflow. Selecting an operating point below approximately 30% wide open may place the fan in an area of instability. Similarly, an operating point beyond 80% wide open typically produces noise and inefficiency. The maximum static efficiency is from approximately 50 to 65% and occurs just to the right of the maximum static-pressure point on the fan performance curve.
Product questions
What is this product?
KAT Series - Double Inlet Centrifugal Fans - Forward Curved is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | KAT Series - Double Inlet Centrifugal Fans - Forward Curved |
| Category | Centrifugal Fan for HVAC |
Specifications Quick Facts • Size from 7 to 18 inches • Capacities to 25,000 m3/h • Total pressure up to 1700 Pa • Suitable for use in packaged unit, AHU, clean room and ventilation Application For supply or exhaust application in commercial, institutions and industrial HVAC systems. Testing Both air and sound performance ratings are based on test to AMCA210 and AMCA300 Standards. All wheels are statically and dynamically balanced to ISO1940 and AMCA204 - G2.5 Standards. Accessories Outlet flanges are available upon request. Construction Wheel The wheel of KAT series is made of galvanized sheet steel forward curved blades. The wheels are specially profiled to obtain a maximum efficiency and low noise level. Housing The housing is manufactured in galvanised sheet steel with the housing fixed to the side plates by means of electric spot welding. A series of holes previously formed in the side plate enable the housing to be mounted in four different orientations. All the unused holes in the side plate are plugged with a plastic cap to prevent air leakage. Frame The frame is manufactured with galvanized angular bars. The frame is fabricated and spot welded to ensures maximum rigidity and in accordance with the allowed dimensional tolerances. Shaft Shafts are manufactured from C45 carbon steel. All shafts are coated with an anti-corrosion varnish after assembly. Bearings Bearings used are either deep groove ball bearing type sealed at both sides. The sealings are self-aligned with an eccentric locking for clamping onto the shaft and is mounted in a rubber housing.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Measuring the wind speed in front of the kitchen hood (Kitchen Hood Face Velocity)
Measuring the wind speed in front of the Kitchen Hood (Kitchen Hood Face Velocity) has the main objective to confirm that the Hood
Read article ↗Related equipment

ADA Series - Direct Coupling Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ADA Series - Double Inlet Centrifugal Fans - Airfoil Wheels
Kruger

ASA Series - Single Inlet Centrifugal Fans - Airfoil Wheels
Kruger

BDB Series - Direct Coupling Double Inlet Centrifugal Fans – Backward Wheels
Kruger
All related articles (77)
- Low Noise Duct Design
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Exhaust duct specs for “Kitchen Exhaust Duct”
- Problems frequently encountered in “Commercial Kitchen System”
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- KRUGER KAT Series
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Calculating the size of the Smoke Exhaust Fan (for exhausting smoke)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Benefits of Cooljet fans for industrial systems
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 impeller types and how centrifugal fans work
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Choosing a Blower for Industrial Work
- Installing Factory Ventilation Fans