EUROVENT
fan/blower EuroVent model MR Model (Backward Curve Direct Drive)
Model / SKU: MR Model
Features - Low noise - Fan blades have a backward direction - Direct drive motor - Fan blades have a special precision - Air flow rate 75-570 m3/min - Centrifugal fan pressure 45-900 mmWG Structure characteristics - Can withstand temperatures up to 90 ° C in transporting polluted air - Can withstand temperatures in transporting liquids up to 350 ° C In addition, the fan is painted with a special aluminum paint suitable for high temperatures and also saves on repair costs - Fan/Blower Produced ac
Share the model, quantity and application so our team can confirm the selection.
Product details
Features - Low noise - Fan blades have a backward direction - Direct drive motor - Fan blades have a special precision - Air flow rate 75-570 m3/min - Centrifugal fan pressure 45-900 mmWG Structure characteristics - Can withstand temperatures up to 90 ° C in transporting polluted air - Can withstand temperatures in transporting liquids up to 350 ° C In addition, the fan is painted with a special aluminum paint suitable for high temperatures and also saves on repair costs - Fan/Blower Produced according to European standards - fan/blower It is a blower with blades and a housing made of white mild steel and stainless steel, making it extremely durable. and has a long service life Helps reduce maintenance costs - Fan/Blower Used in industrial applications from small to large sizes, suitable for work with little dust. Applications - Suitable for use in rubber drying plants. Air delivery system - suitable for use as a fan to extract smoke from furnaces. or work from welding - suitable for use in suction systems Forced suction system Send rice grains, sawdust, wood dust mixed in the air. Except for materials such as various fibers - the main highlight is that it can send out a lot of air. It can send material out of the propeller. Then send it along with air - suitable for using power and not overloaded, causing no problems with the motor. Even though the entrance to the fan is fully opened - suitable for use in wood factories. industrial plant cement factory Ceramic factories, tanneries, steel smelting factories - Suitable for use in chemical factories and others that need to remove unwanted air - Suitable for use in ventilating wood shops, machinery industries - Suitable for use in ventilating cement factories, ceramic factories, tanning industries, chemical industries.
Product questions
What is this product?
fan/blower EuroVent model MR Model (Backward Curve Direct Drive) is listed under Fans and blowers, brand EUROVENT, model / SKU MR Model.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | EUROVENT |
|---|---|
| Model / SKU | MR Model |
| Category | Centrifugal Fans |
Features - Low noise - Fan blades have a backward direction - Direct drive motor - Fan blades have a special precision - Air flow rate 75-570 m3/min - Centrifugal fan pressure 45-900 mmWG Structure characteristics - Can withstand temperatures up to 90 ° C in transporting polluted air - Can withstand temperatures in transporting liquids up to 350 ° C In addition, the fan is painted with a special aluminum paint suitable for high temperatures and also saves on repair costs - Fan/Blower Produced according to European standards - fan/blower It is a blower with blades and a housing made of white mild steel and stainless steel, making it extremely durable. and has a long service life Helps reduce maintenance costs - Fan/Blower Used in industrial applications from small to large sizes, suitable for work with little dust. Applications - Suitable for use in rubber drying plants. Air delivery system - suitable for use as a fan to extract smoke from furnaces. or work from welding - suitable for use in suction systems Forced suction system Send rice grains, sawdust, wood dust mixed in the air. Except for materials such as various fibers - the main highlight is that it can send out a lot of air. It can send material out of the propeller. Then send it along with air - suitable for using power and not overloaded, causing no problems with the motor. Even though the entrance to the fan is fully opened - suitable for use in wood factories. industrial plant cement factory Ceramic factories, tanneries, steel smelting factories - Suitable for use in chemical factories and others that need to remove unwanted air - Suitable for use in ventilating wood shops, machinery industries - Suitable for use in ventilating cement factories, ceramic factories, tanning industries, chemical industries.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Low Noise Duct Design
Low Noise Duct Design is a matter of controlling air speed + pressure + vibration + selecting equipment. From the origin to the di
Read article ↗Related equipment
All related articles (73)
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to choose the right blower for the job
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Design of air conditioning and ventilation systems for food court areas in department stores.
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Blower
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- Benefits of Cooljet fans for industrial systems
- Why improve working conditions for employees? Operators are therefore important.
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- An Exhaust Fan: a Useful Household Appliance
- Basic ventilation airflow calculations
- 5 impeller types and how centrifugal fans work
- 5 ways to use fans while saving electricity
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- 6 wastewater treatment systems
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Understanding blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- What causes blower vibration, and what should be checked?
- Selecting Fans and Blowers: Information to Prepare before Comparing Models
- Managing Heat in Buildings and Factories
- Choosing a Blower for Industrial Work
- Installing Factory Ventilation Fans