• Specifically designed for direct connection with industrial circular ducting of standard diameter. • Incorporate a powerful motor which is factory matched to a mixed flow impeller. • Delivers high airflow performance with minimum noise generation and high static pressure typically found in ducted ventilation systems.
Share the model, quantity and application so our team can confirm the selection.
Product details
• Specifically designed for direct connection with industrial circular ducting of standard diameter. • Incorporate a powerful motor which is factory matched to a mixed flow impeller. • Delivers high airflow performance with minimum noise generation and high static pressure typically found in ducted ventilation systems.
Product questions
What is this product?
MTD Series - In-Line Mixed Flow Duct Fan is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | MTD Series - In-Line Mixed Flow Duct Fan |
| Category | Ventilation fans for buildings and residences |
Specifications Quick Facts • Suitable for ducted ventilation system • Size from 100 to 315 mm • Capacities to 1800 m3/h • Easy Installation and maintenance Operating Temperature Maximum operating temperature +40 degC Motor MTD Series fans are fitted with direct connection two speed motors as standard with thermal over load protection. All motors are suitable for speed control regulation using electronic or auto-transformer. Accessories Grilles Mounted at the inlet or outlet of the fan, the grille prevents the entry of any foreign objects. Back-Draft Shutter Mounted at the outlet of the MTD fan, the shutter prevents the air recirculating when the fan is not in use. Rectangular Duct Adapters The adapter enables the MTD fan to be connected to rectangular ducting. Construction MTD models are manufactured in tough reinforced plastic, except models 100, 250/1, 250/2 & 315 in steel casing and finished in tough epoxy-polyester paint coating. Impeller blades moulded in tough ABS plastic, except models 250/1, 250/2 & 315, constructed from pressed galvanised sheet steel.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Low Noise Duct Design
Low Noise Duct Design is a matter of controlling air speed + pressure + vibration + selecting equipment. From the origin to the di
Read article ↗Related equipment
All related articles (78)
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- Design of air conditioning and ventilation systems for food court areas in department stores.
- KRUGER MTD Series
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Why improve working conditions for employees? Operators are therefore important.
- Fan doesn't spin. Easy way to fix it yourself.
- loud fan with how to solve it yourself
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- 3 Ways to Address Stiff Fan Gears
- An Exhaust Fan: a Useful Household Appliance
- Which Fans Should You Install in a New House?
- 3 Tips for Addressing a Noisy Fan
- Basic ventilation airflow calculations
- Removing dark fan stains with wheat flour
- 5 ways to use fans while saving electricity
- Simple fan cleaning
- Does an air-conditioned bedroom need an exhaust fan?
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Installing Factory Ventilation Fans