Low profile Mixed Flow fans with sound-absorbent insulation Extremely quiet. The low profile of the MTD Silent fans makes the most effective solution for installations where space is limited such as in ceiling voids. Both air and sound performance ratings are tested and certified by AMCA, in accordance to AMCA211 and AMCA311 Standards.
Share the model, quantity and application so our team can confirm the selection.
Product details
Low profile Mixed Flow fans with sound-absorbent insulation Extremely quiet. The low profile of the MTD Silent fans makes the most effective solution for installations where space is limited such as in ceiling voids. Both air and sound performance ratings are tested and certified by AMCA, in accordance to AMCA211 and AMCA311 Standards.
Product questions
What is this product?
MTD Silent Series - In-Line Mixed Flow Duct Fan is listed under Kruger, brand Kruger.
How can I request a price and confirm this model?
Enter the model, quantity and application in the quotation form, then send the prepared message by email or LINE to SPI using the contact details on this website. Confirm the price and model with the team before ordering.
Technical specifications
| Brand | Kruger |
|---|---|
| Model / SKU | MTD Silent Series - In-Line Mixed Flow Duct Fan |
| Category | Ventilation fans for buildings and residences |
Specifications Quick Facts • Suitable for ducted ventilation system • Size from 100 to 315 • Capacity up to 1877 m3/h • High performance with significant noise reduction Motors MTD Silent 100/2~200/2 • Speed controllable 230V -50HZ motor, of two speed motors. IP 44. • Motors are Class B, with ball bearings and safety thermal overload protection. MTD Silent 250~315 • IP 44. External terminal box IP 55. • Removable fan body with two speed motor, single phase 230V-50/60 Hz speed controllable, Class F, external rotor aluminium motor with capacitor and thermal protection. Additional Information The models offer solutions to ventilation problems, especially in places where people work and low sound level is required. Accessories MCA-S • Non-return flaps to be installed at the fan discharge. They prevent heat leakages when the extractor is not operating. MRJ-S • Grilles mounted at the inlet or outlet of the fan to prevent the entry of any foreign objects that could damage the fan. MBR-S • Flanges allowing the coupling of MTD-Silent fans in series. MAR-S • Rectangular Duct Adapters enable connection to rectangular ducting. MPC-S • Flow detectors designed to correctly measure pressures at the inlet with airflow straightener. Construction MTD Silent 100/2~200/2 General • Manufactured in plastic material, with a specifically designed internal skin to direct the sound waves in the right angle for them to be captured by the sound-absorbent material Fitted with rubber gaskets on the inlet and outlet to absorb vibrations, a body that can be dismantled. • Connection box can be rotated 360°, to facilitate easy connection of the power cable. • The low profile of the MTD Silent fans makes them the most effective solution for installations where the space of installation is limited such as false ceilings. Motors • Speed controllable 230V -50HZ motor, of two speed motors. IP 44. • Motors are Class B, with ball bearings and safety thermal overload protection. MTD Silent 250~315 General • Constructed from sheet steel with epoxy polyester paint, acoustic insulation (MO) glass fiber, within outer shell. • Aerodynamic inlet to improve air flow and reduce sound. Detachable fan unit without demounting duct connections. • The models offer solutions to ventilation problems, especially in places where people work and low sound level is required.
Documents & catalogs
Source references
MCG Trading · Source catalog ↗Related reading

Duct sizing with Equal Friction
Duct sizing with ( Equal Friction) Equal Friction is a duct-sizing method that keeps the pressure loss from friction per unit duct
Read article ↗
Design and installation of air duct systems (Duct Design)
Design and installation of air duct systems (Duct Design) Design air ducts for air conditioning systems. Why do you need to "reduc
Read article ↗
Low Noise Duct Design
Low Noise Duct Design is a matter of controlling air speed + pressure + vibration + selecting equipment. From the origin to the di
Read article ↗Related equipment
All related articles (78)
- Department store bathrooms with air conditioning have to think about 2 at the same time to suck out odors and moisture.
- What is the Aspect Ratio of the air duct?
- How to design air ducts (Duct Design) according to international standards
- Calculation of large meeting room air conditioning systems (High Density Occupancy)
- Standards for air speed in ducts (Duct Velocity)
- Air conditioning system (negative pressure room)
- Summary of professional guidelines for reducing pressure drop
- Air conditioning system "negative pressure room"
- Choosing an air distributor (Air Diffuser / Grille / Register)
- What is External Static Pressure (ESP) and how important is it?
- Procedure for measuring ESP (External Static Pressure) at Fan In / Fan Out
- Balancing air volume is the most important thing in cleanroom work.
- Creating a positive pressure room (Positive Pressure Room) is the heart of HVAC system work.
- Round pipe or square pipe, which one is best to use for HVAC design?
- How to calculate the size of a ventilation fan for a factory with a height of 6 meters, simple and practical.
- Cleanroom Design
- Fresh Air Supply Methods
- What are System Effects?
- In-depth look at factory fan types: Axial vs Centrifugal, which one is right for your job?
- The reason why Centrifugal Fan "wind does not reach as designed"
- Analysis of Condensation at the Air Pipe
- System effect of the fan (Fan)
- Kruger Fan Kruger Fan
- Kruger
- Design of air conditioning and ventilation systems for food court areas in department stores.
- KRUGER MTD Series
- Principle of “Adjusting the air volume of the VAV system (Variable Air Volume)”
- Balancing pressure for clean rooms
- Design of air conditioning system for isolation room (Isolation Room)
- Design of air conditioning system for large meeting rooms
- Selecting the size of the air diffuser (Air Diffuser)
- Air conditioning units must have “Fill in fresh air (Fresh Air)”
- Namsae Trading ventilation fan, strong wind, durable, cool factory.
- Relationship between Flow Rate and Pressure Drop
- Calculating Louver size for Fresh Air Intake
- Formation of water droplets on the surface of cold water pipes in air conditioning systems.
- Factory fan, high wind power Namsae Trading
- Design of a fire escape air compressor system (Stair Pressurization System)
- Adjusting the air balance in a rectangular duct system (Rectangular Duct)
- industrial fan
- Calculation of air volume CFM (Cubic Feet per Minute)
- Duct Design
- Air duct work (ductwork)
- ACH stands for Air Changes per Hour.
- Positive Pressure Room
- What is the Static pressure value in the Air Nozzle Catalog?
- Fan Fan
- How are PIP ventilation pipes better than galvanized pipes?
- How to cool down the factory space?
- Why improve working conditions for employees? Operators are therefore important.
- Fan doesn't spin. Easy way to fix it yourself.
- loud fan with how to solve it yourself
- How can air changes improve factory air quality?
- A cost-effective and efficient way to cool a factory
- How good is a ventilation fan? Which type is appropriate to use?
- Useful Facts about Industrial Fans
- 3 Ways to Address Stiff Fan Gears
- An Exhaust Fan: a Useful Household Appliance
- Which Fans Should You Install in a New House?
- 3 Tips for Addressing a Noisy Fan
- Basic ventilation airflow calculations
- Removing dark fan stains with wheat flour
- 5 ways to use fans while saving electricity
- Simple fan cleaning
- Does an air-conditioned bedroom need an exhaust fan?
- Industrial fans, blowers and ventilation systems for workers' quality of life
- Ventilation basics
- Notes on ventilation in industrial systems
- The difference between fans and blowers
- Benefits of ventilation systems
- 9 tips for inspecting and maintaining blower fans
- Tips for managing heat inside buildings
- Selecting Kruger Fans: Search by Series and Check Documents before Comparing Models
- Managing Heat in Buildings and Factories
- Installing Factory Ventilation Fans